Apartment handover, riser testing, sectional completion

    Commissioning software for towers where each apartment has to complete on its own record.

    A residential tower repeats an apartment fit-out hundreds of times up a building whose risers, smoke control and life safety systems only work as a whole. Deskely tracks each apartment as an instance of a templated record while riser, smoke control and central plant scopes run as their own subsystems, so sectional completion is issued floor by floor with real evidence behind it.

    Unit
    Apartment, repeated by floor
    Shared
    Risers and smoke control
    Structure
    Sectional completion
    Gate
    Floor-by-floor handover
    TOWER A — RESIDENTIAL FLOORS 8-32TOWER SYSTEMS RECORD SET · REV CRESIDENTIAL TOWERRETAIL PODIUMPOD-MEP-01Level 12 snag open340 UNITS · 22 RETAIL BAYSTAG REGISTERFCU-12-03Fan coil unit, apartment …Records signedAHU-04Residential floor fresh a…In testBMS-CTRL-07Podium retail controllerPreservationSMK-EX-01Stairwell pressurisation …Punch open340 unitsunder one system hierarchy

    The problem

    Four hundred apartments, one riser, and a smoke control system that only makes sense as a whole.

    Each apartment repeats the same fit-out — kitchen, bathroom, heating and ventilation, electrical and finishes — but sits on shared risers, a communal smoke control system and central plant that no single apartment owns.

    Developers frequently need sectional completion, releasing sold apartments floor by floor while construction and commissioning continue above, which paper snagging lists cannot report reliably.

    Deskely templates the apartment record once while modelling risers, smoke control and central plant as their own subsystems, so a floor's readiness reflects both its apartments and the shared systems it depends on.

    THE RISER MAKES NO SENSE APARTMENT BY APARTMENTResidential tower, floors 1–40Smoke control and pressurisation only work as a whole-riser system, not per unitFloor 40 — apt handover checkoutFloor 36 — apt handover checkoutFloor 32 — apt handover checkoutFloor 28 — apt handover checkoutFloor 24 — apt handover checkoutFloor 20 — apt handover checkoutFloor 16 — apt handover checkoutFloor 12 — apt handover checkoutRiserFloor 28apartment checkout complete, riser test still openDeskely runs apartment checkout and riser testing on separate tracks that meet at each floor.

    Setting up the register

    Apartments, floors and shared risers are structured to match the handover strategy.

    A single apartment template — pre-functional checks, heating and ventilation, electrical, wet areas, finishes and snagging — is defined once and applied to every unit, keyed to the apartment number.

    Risers, smoke control, sprinkler mains, communal plant, lift systems and life safety are modelled as separate subsystems that individual apartments depend on for their own completion.

    Drawings, apartment schedules and riser diagrams are parsed into that structure, so the register reflects the actual sectional completion boundaries agreed with the employer's agent.

    1 · SOURCE DOCUMENTSM&E drawings rev C88 sheetsApartment fan coil sched…340 unitsRetail podium equipment …42 tenanciesFire alarm zone schedule32 floorsPARSE + MATCHtag · description · drawing ref2 · ONE TAG REGISTERFCU-12-03Fan coil unit, apartment …LEVEL 12AHU-04Residential floor fresh a…LEVEL 12BMS-CTRL-07Podium retail controllerCONTROLSSMK-EX-01Stairwell pressurisation …LIFE SAFETYTWO DOCUMENTS DISAGREEM&E drawings rev CPodium retail controllerApartment fan coi…Abbreviated descriptionEngineer picks the sourcedecision loggedWeeks of transcription become a draft an engineer reviews.

    Execution

    Apartment checkout and riser testing run on separate tracks that meet at each floor.

    Apartment pre-functional checks, functional testing and snagging are captured on tablet unit by unit, with photos recorded against known defect categories.

    Riser pressure testing, smoke control commissioning and communal life safety cause and effect testing are recorded against the floors and zones they serve, independent of individual apartment fit-out progress.

    Punch is categorised by whether it blocks that specific apartment's handover or the floor's sectional completion, so one unfinished unit does not automatically hold up its neighbours.

    SECTIONAL COMPLETION, FLOOR BY FLOORTower, floors 1–40Riser and smoke control commissioning100%Apartment checkout, floors 1–20100%Apartment checkout, floors 21–4065%Riser test aligned with floor checkout55%Sectional completion certificate20%20 of 40floors sectionally complete0apartments handed over ahead of riser proofSectional completion is issued once the riser test aligns with that section's apartments.

    Sectional completion and handover

    Sections complete on evidence, with life safety proven before anyone moves in.

    Sectional completion certificates are issued per floor or per core from the underlying apartment and riser records, with smoke control and life safety testing proven as a prerequisite for that section.

    Individual apartment handover packs — O&M information, warranties, settings and snagging history — are exported to each purchaser or occupier as their unit completes, rather than compiled centrally at the very end.

    Outstanding defects are carried into the defects liability period against the specific apartment or riser they belong to, with an owner and a date attached.

    Level 12 — legal completion ladderCompletion issues only from signed unit and system recordsICInstallation completeRecords signed 12 NovApartment FCU installation records20 / 20 signedFire stopping and containmentcompleteFTFunctional testIn test — awaiting fresh air unitUnit ventilation loop test17 / 20Stairwell pressurisation testedconfirmedLCLegal completionPunch open — 6 itemsBlocking punch6 openDeveloper sign-offnot witnessed

    How it runs

    From core and shell to a section ready to occupy.

    Residential towers combine extreme repetition with shared critical systems, which is exactly the combination structured templating and subsystem modelling are built to handle.

    1. 01

      Template the apartment

      One pre-functional, functional and snagging record set defined once and applied to every apartment by number.

    2. 02

      Model risers and shared systems

      Risers, smoke control, communal plant and life safety modelled as subsystems that apartments depend on for completion.

    3. 03

      Run checkout on two tracks

      Apartment fit-out and riser/smoke control testing captured independently, each against its own record set.

    4. 04

      Issue sectional completion

      Certificates issued per floor or core once apartment and shared system records agree, with defects carried by owner.

    FAQ

    Questions about Mixed-use and residential towers scopes.

    Ready to digitize
    commissioning and
    handover?