New mains swabbed, pressure tested, disinfected and sampled before they carry supply

    Commissioning software for reservoirs and networks where every new main, valve and service reservoir has to be proven clean and pressure-tight before it joins the live network.

    New trunk mains, distribution mains and service reservoirs cannot simply be connected to a live network — each section is swabbed, pressure tested, chlorinated, flushed and bacteriologically sampled before it is declared fit for supply, and a service reservoir is structurally inspected, cleaned and disinfected before it holds wholesome water. Deskely holds every main section, valve, reservoir cell and sample point in one register with the disinfection and fit-for-supply gates built in.

    Assets
    Main sections, valves, reservoir cells
    Test
    Swab, pressure test, disinfection, bacti sample
    Interface
    Live distribution network and DMA boundary
    Gate
    Fit-for-supply sign-off
    TRUNK MAIN — SECTION SETMAIN LAY RECORD SET · REV ATRUNK MAIN — SECTION 14SERVICE RESERVOIR — CELLS A / BNETWORKMAIN-14Bacteriological sample pendingTAG REGISTERMAIN-14Trunk main, section 14Records signedVLV-14-02Isolation valve, section …In testRES-CELL-AService reservoir, cell APreservationSAMPLE-14Bacteriological sample po…Punch open32 sectionsunder one asset register

    The problem

    A network scheme is hundreds of pipe sections, and a spreadsheet cannot show which one has actually passed its bacti sample.

    A trunk main or distribution network scheme is built in sections by different civil crews over months, each section needing its own swab, pressure test, chlorination and — critically — a clear bacteriological sample before it can be connected live.

    When swabbing records, pressure test charts and lab sample results sit in a site engineer's notebook and a separate lab portal, nobody can confirm at connection which sections have a clear sample and which are still awaiting a retest after a failed result.

    Deskely tags every main section and reservoir cell individually, so fit-for-supply status is reported section by section instead of assumed from a general contractor sign-off before a live connection is made.

    WHICH SECTION HAS A CLEAR BACTI SAMPLETrunk main — 8 sectionsSwab, pressure test, chlorinate, flush, sample — a lab result decides if a section can go liveS1clearS2clearS3clearS4failed sampleS5clearS6clearS7failed sampleS8clearSITE NOTEBOOK vs LAB PORTALSection S4 — swab and pressure testSite engineer's notebookSection S4 — bacti sample, 1st attemptLab portal, failed resultSection S4 — re-flush and re-sampleNot yet requested2sections with a failed sample, retest untracked8sections that could be joined to the live networkDeskely tracks a failed sample and its retest against the exact section, not a scheme average.

    Setting up the register

    Main sections, valves and reservoir cells are tagged assets matched to the network schematic.

    Network schematics, main lay drawings and reservoir general arrangement drawings are parsed into a reviewed register, so every main section, valve chamber and reservoir cell carries its chainage, its material and its design pressure from day one.

    Swabbing checklists, hydrostatic pressure test templates and disinfection and bacteriological sampling sequences are defined once and instantiated across every section, so a scheme with two sections or two hundred uses the same proven test set.

    Reservoir structural inspection, cleaning and cell-by-cell disinfection are held as their own record set, distinct from main commissioning, because a reservoir often has its own separate fit-for-supply gate before it is brought online.

    1 · SOURCE DOCUMENTSNetwork schematics6 sheetsMain lay drawings32 sectionsReservoir general arrang…2 cellsValve schedules48 valvesPARSE + MATCHtag · description · drawing ref2 · ONE TAG REGISTERMAIN-14Trunk main, section 14SECTION 14VLV-14-02Isolation valve, section …SECTION 14RES-CELL-AService reservoir, cell ARESERVOIRSAMPLE-14Bacteriological sample po…SECTION 14TWO DOCUMENTS DISAGREENetwork schematicsTrunk main, section 14Main lay drawingsAbbreviated descriptionEngineer picks the sourcedecision loggedWeeks of transcription become a draft an engineer reviews.

    Execution

    Swabbing, pressure testing and disinfection are proven section by section before a live connection is made.

    Each main section is swabbed to remove construction debris and hydrostatically pressure tested to its design pressure before being chlorinated to a specified concentration and contact time, with results captured against the exact section rather than the scheme as a whole.

    Following chlorination, sections are flushed and a bacteriological sample is taken and sent to a laboratory; a failed result triggers a re-flush and re-sample against the same section, so the retest history is never lost.

    Reservoir cells follow the same discipline — structural inspection, cleaning, disinfection and sampling — logged per cell, so a two-cell reservoir can bring one cell into supply while the other remains under test.

    SWAB, PRESSURE TEST, DISINFECT, SAMPLESection S4, 0.6 kmSwabPressure testChlorinateFlush + sampleFit for supplySwab and debris removal recordCivil contractorHydrostatic pressure test to design pressureCivil contractorChlorination concentration and contact timeCommissioning team1st bacteriological sample — failedLaboratoryRe-flush and 2nd bacteriological sampleLaboratory1retest cycle open on section S47 of 8sections fit for supplyA section joins the live network on a clear sample, tracked against that exact section.

    Fit-for-supply sign-off and handover

    A section joins the live network on a clear sample, not on an assumption that yesterday's flush was probably enough.

    Fit-for-supply sign-off draws on the same swabbing, pressure test and bacteriological sample records built during commissioning, so the evidence the water company's water quality team requires before a live connection is an export rather than a phone call to the lab.

    The handover pack for the network operations team includes as-built main lay drawings, valve schedules and reservoir inspection reports keyed to the asset register, ready for network operations from the moment supply begins.

    Every signature carries a name, role and timestamp, which is what the water company's water quality and network teams expect before a section is declared live rather than provisionally connected.

    AUDIT QUERYMAIN-14Section 14, bacti sample pendingComplete evidence chain for MAIN-14SW-14Swabbing recordSite engineer03 JunPT-14Hydrostatic pressure testSite engineer05 JunBS-14Bacteriological sampleLaboratorypendingCERTIFICATEFS-14Fit-for-supply sign-off — Section 14pendingWater quality teamPrerequisites demonstratedThe certificate cannot issue until a clear bacteriological sample is returned for this section.

    The dossier

    Proof a new main is clean before it joins the live network.

    Every new main and service reservoir carries its own swabbing, pressure and disinfection record before a water company will accept it into supply. The dossier has to trace each length of pipe and each reservoir cell back to a signed test, not a general statement of completion.

    RECORDS PRODUCED6 typesPipeline swabbing and flushing…Completed immediately after pipe laying…Hydrostatic pressure test…Performed section by section once…Disinfection and contact time…Carried out after a successful pressure…Bacteriological sampling…Taken after disinfection water has been…Reservoir structural and roof…Completed before the reservoir is first…Fit-for-supply sign-off…Signed by the water company before the…DOSSIERIndexed persubsystem and tagExport readyEach record lands in the same structure, so the dossier assembles itself.

    Pipeline swabbing and flushing record

    The main has been swabbed and flushed to remove construction debris before pressure testing begins.

    Completed immediately after pipe laying and jointing, before hydrostatic test.

    Hydrostatic pressure test certificate

    The main holds test pressure for the specified duration with pressure loss inside the allowable tolerance.

    Performed section by section once swabbing is complete.

    Disinfection and contact time record

    The main or reservoir has been dosed to the required chlorine concentration and held for the specified contact time.

    Carried out after a successful pressure test, before sampling.

    Bacteriological sampling certificate

    Water quality samples taken after disinfection and flushing meet the drinking water bacteriological standard.

    Taken after disinfection water has been flushed from the main or reservoir.

    Reservoir structural and roof inspection record

    The service reservoir structure, roof and access covers are sound and free of ingress points before it holds potable water.

    Completed before the reservoir is first filled with disinfection water.

    Fit-for-supply sign-off certificate

    Swabbing, pressure testing, disinfection and sampling are all complete and signed for the asset entering supply.

    Signed by the water company before the main or reservoir is connected live.

    How it runs

    From pipe laying to a live, sampled connection.

    Network schemes reward a register that treats every section as its own asset, because a single missed bacteriological sample is exactly what a water quality incident review will trace back to.

    1. 01

      Model the network by section

      Main sections, valves and reservoir cells modelled as assets tied to the network schematic.

    2. 02

      Parse the network design

      Main lay drawings and reservoir general arrangements drafted into a reviewed register with chainage and pressure data attached.

    3. 03

      Template swab, test and disinfection

      Swabbing, pressure test and disinfection sequences defined once, instantiated across every section and cell.

    4. 04

      Gate connection on a clear sample

      Fit-for-supply sign-off reported from a clear bacteriological sample, with retests tracked against the same section.