SLDResources / SLD symbols / Switching devicesUpdated 29 Oct 2026

Draw-out circuit breaker symbol

Also called Withdrawable breaker, Racked breaker

A circuit breaker on a truck that racks out of the switchgear, which isolates it and lets it be removed for maintenance.

ANSI / IEEE
IEC 60617 · S00287

What the draw-out circuit breaker symbol means

A circuit breaker on a truck that racks out of the switchgear, which isolates it and lets it be removed for maintenance.

ANSI and IEC symbols

ANSI / IEEE 315

The breaker square with a chevron on each side, showing the disconnecting contacts.

ANSI SVG
IEC 60617S00287

Circuit breaker, drawn withdrawable. The IEC breaker with chevrons for the plug-in contacts on each side.

IEC SVG

Where you see it

Medium voltage switchgear and large low voltage power circuit breakers.

What is written next to it

On a one-line, the draw-out circuit breaker carries its tag and its ratings: rated voltage and current and breaking current in kA.

What gets checked at commissioning

Before the draw-out circuit breaker is energised, the test records usually cover: the breaker tests plus racking in and out, shutters, the test position and the interlocks between them. Each check is recorded against the tag, so the system can be handed over with its evidence. See commissioning software.

ANSI device numbers

Protective functions you will often find with a draw-out circuit breaker:

  • 52 AC circuit breaker

See the full list of ANSI device numbers with their IEC equivalents.

Frequently asked questions

What does the draw-out circuit breaker symbol look like?

On ANSI drawings: The breaker square with a chevron on each side, showing the disconnecting contacts. In IEC 60617: The IEC breaker with chevrons for the plug-in contacts on each side.

Is the draw-out circuit breaker symbol the same in IEC and ANSI?

No. The IEC breaker with chevrons for the plug-in contacts on each side. The IEC 60617 number is S00287.

Where is a draw-out circuit breaker used?

Medium voltage switchgear and large low voltage power circuit breakers.

Which ANSI device numbers go with a draw-out circuit breaker?

52 AC circuit breaker.